Traffic and street traffic for temporary shoring design adjacent to the public way.
Live load retaining wall.
For crib walls for extreme event limit state i live load surcharge is not considered where.
Dc the self weight of structural components.
Ev the self weight of the soil above the heel of a footing in a semi gravity retaining wall or of the reinforced soil in a mse.
The weight of a building or another retaining wall above and set back from the top of the wall are examples of dead load surcharges.
Chapter 14 retaining walls july 2020 14 7 14 1 introduction retaining walls are used to provide lateral resistancefor a mass of earth or other material to accommodate a transportation facility.
Eqe dynamic.
Each of these walls must be designed to resist the external forces applied to the wall from earth pressure surcharge load water earthquake etc.
For comparison this surcharge is significantly larger than highway live load surcharge which is typically simplified to 250 psf ft.
It can be either dead loads for example sloping backfill above the wall height or live load which could result from the highway or parking lot paving or adjacent footing.
Ls live load surcharge.
Prior to completing any retaining wall design it is first necessary to calculate the forces acting on the wall.
Retaining wall to support a cut.
The walls are used in a variety of applications se including right of way restrictions protection of existing structures that must remain in place.
Surcharge loads acting on retaining wall.
In the conventional design of retaining walls and bridge abutments the lateral earth pressure due to live load surcharge is estimated by replacing the actual highway loads with a 600 mm layer of backfill.
Surcharge loads shall be applied where vehicular load or pedestrian loads are expected to act on the surface behind a shored excavation or retaining wall within a distance equal to the height of the excavation or wall.
Construction since it is the most critical section of wall stem in wall design.
This original recommendation was made several decades ago when the highway truck loads were much lighter.
Eh static soil lateral load.
The train live load surcharge may greatly.
Retaining wall design the applicable train live load surcharge is the cooper e80 which can be approximated as 1 880 pounds per square foot per foot psf ft of rail.
Steel has very high tensile strength but can bend easily due to its small cross section.
Missing concrete or pool consolidation and foreign object intrusion in the wall base section will reduce support to the steel and can cause wall failure.