C955 standard specification for load bearing transverse and axial steel studs runners tracks and bracing or bridging for screw application of gypsum panel products and metal plaster bases e72 standard test methods of conducting strength tests of panels for building construction.
Load bearing metal studs specs.
Canadian steel l stud framing sizes refers to the construction of walls and planes using cold formed steel components.
Compared to steel deck options cfmf floor joists may be appealing because of their span capabilities without the use of shoring.
Unshored composite steel deck construction.
The steel network provides solutions for all standard light steel framing applications including load bearing mid rise construction systems.
There are two main components of steel stud framing a stud and a track.
It eliminates box beam headers stud to track nesting built up members for posts and jambs and has superior axial strength for load bearing projects.
Steel studs are not designed for bearing any axial loads and are ideal for supporting the dead load of many typical wall finishes such as gypsum board tile etc and providing resistance to limited interior transverse loads.
Lightweight cold formed galvanized steel load bearing studs are available in a selection of sizes flanges gauges and yield strengths to obtain optimal performance.
Apply gypsum board horizontally or vertically in single or multiple layers.
Load bearing members start at a thickness of 33mils 20ga and can be as thick as 97mils 12ga.
Hds allowable limiting heights contact clarkdietrich technical services at 888 437 3244 for any questions on the design systems above.
1 splicing of studs is not suitable for load bearing walls.
Metal products are to meet or exceed all applicable astm standards.
Steel stud p artitions steel stud gypsum board partitions are comprised of steel floor and ceiling tracks steel studs and gold bond brand gypsum board which is attached with drywall screws.
Tsn s optimized stiffwall shear wall system used together with sigmastud s increased load capacity will allow you to build taller lighter faster and stronger.
For best non structural steel stud specifications stay apprised of industry standard requirements.
Stiffwall uses rd the screws of other steel framed shear walls and the strap.
Heavier gauge steel studs are used in load bearing walls and structural applications such as exterior walls.
Specifications track fixings at 600mm centres fixings at 600mm centres 100mm max to first fixing wall stud.
An 8 foot 3 1 2 inch metal stud for instance may support over 2 000 pounds while a 16 foot stud of the same width will support as little as 400 pounds.
Structural steel stud and track selection is based on the loads they will be.